Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
configuration:usb-serial-adapter [2017/09/18 10:59]
gray created
configuration:usb-serial-adapter [2021/11/12 14:59] (current)
schmitt
Line 1: Line 1:
  
-====== ​Set up a USB device with a serial interface ​on an NB1600 ​router. ======+====== USB device with a serial interface ​====== 
 + 
 + 
 +In this page description to set up a USB adapter with a RS 232 interface for a NB1600. ​The description leads through the setup of the USB adapter and the establishment of the serial interface. It also describes how to set the serial interfaces as client and server. 
 + 
 +===== set up the USB device =========== ​ 
  
 In the web interface, you can  enable the tab "USB Administration"​ under the tab INTERFACES. In the web interface, you can  enable the tab "USB Administration"​ under the tab INTERFACES.
  
-{{:​configuration:​interfaces_1.png?​direct&​900|}}+{{:​configuration:​usb_administration.png?​direct&​900|}}
  
 Under the “Devices” tab, the detected USB adapter should be listed under "​Connected USB Devices"​. If the column is empty, you can use the Refresh button to refresh the pages for the display of the USB device. Under the item "​Enabled USB Devices"​ you can use the add button to release the recognized USB device. Under the “Devices” tab, the detected USB adapter should be listed under "​Connected USB Devices"​. If the column is empty, you can use the Refresh button to refresh the pages for the display of the USB device. Under the item "​Enabled USB Devices"​ you can use the add button to release the recognized USB device.
Line 15: Line 21:
  
 After confirming the entries, the serial interface is displayed under the item "​Enabled USB Devices"​. After confirming the entries, the serial interface is displayed under the item "​Enabled USB Devices"​.
 +
 +
 +==== set up the serial port ====
 +
  
 {{:​configuration:​Enabled_USB_Devices_4.png?​direct&​900|}} {{:​configuration:​Enabled_USB_Devices_4.png?​direct&​900|}}
Line 20: Line 30:
 Under the menu item "​Serial"​ you can now administrate the serial port. Use the edit button to customize the serial port. Under the menu item "​Serial"​ you can now administrate the serial port. Use the edit button to customize the serial port.
  
-{{:​configuration:​Serial_Port_Admin_5.png?​direct&​900|}}+{{:​configuration:​Serial_Port_Administration.png?​direct&​900|}}
  
 For this, a new window is opened, in which you can select a "login console"​ or "​device server"​ from the serial port. For this, a new window is opened, in which you can select a "login console"​ or "​device server"​ from the serial port.
  
-{{:​configuration:​Serial_6.png?​direct&​900|}}+{{:​configuration:​Admin_Console_seriell.png?​direct&​900|}}
  
 If the option "​device server"​ has been selected, you have the possibility to set the serial interface. If the option "​device server"​ has been selected, you have the possibility to set the serial interface.
  
-{{:​configuration:​device_server_7.png?​direct&​900|}}+{{:​configuration:​Administration_DeviceServer.png?​direct&​900|}}
  
 Under the window "Port Settings"​ you have the possibility to set parameters for the serial interface and the server. Under "Allow clients from" you can restrict access to the server to a network. Under the window "Port Settings"​ you have the possibility to set parameters for the serial interface and the server. Under "Allow clients from" you can restrict access to the server to a network.
  
-{{:​configuration:​Port_Settings_8.png?​direct&​900|}}+{{:​configuration:​Port_Settings1.png?​direct&​900|}}
  
  
 After confirming the entries, the changes are accepted. In the web interface, you can now use the tab "USB Administration"​ under the tab INTERFACES. After confirming the entries, the changes are accepted. In the web interface, you can now use the tab "USB Administration"​ under the tab INTERFACES.
  
-{{:​configuration:​Interfaces_device_server_9.png?​direct&​900|}}+{{:​configuration:​SerialPortAdministration_2.png?​direct&​900|}} 
 + 
 + 
 +===== Login and Testing ===== 
  
 For testing, one can use the internal serial interface of the NB1600 and connect it to thea USB adapter. So with a device server and the login console will be forwarded For testing, one can use the internal serial interface of the NB1600 and connect it to thea USB adapter. So with a device server and the login console will be forwarded
  
-{{:​configuration:​Testing_Interfaces_10.png?​direct&​900|}}+{{:​configuration:​SerialPortAdministration_2.png?​direct&​900|}}
  
 Telnet can be used to access the NB1600. Telnet can be used to access the NB1600.